A cable net structure is subject to vertical loads applied at its interior nodes:

Geometry

Cable area: 0.01 [ft2]
Modulus of elasticity: 3.6×106 [ksf]; Poisson’s ratio: 0.0
Supports: exterior nodes: all DOFs fixed

Loads

as shown above

Reference

“Midas” Verification manual.The manual presents results from three references:
1. John W. Leonard, Tension Structures 1988, pp115-7, McGraw Hill book company.
2. A. Lo, Nonlinear dynamic analysis of cable and membrane structures, 1981, Ph.D. Dissertation, Oregon State University.
3. Baron & Vendatesan, Nonlinear Analysis of cable and truss structures, ASCE, Vol 97, pp. 679-710, 1971, Journal of the Structural Division.

Comparison of Results

Beam/Node Result type Result Deviation
Theoretical STRAP
Ref.1 Ref.2 Ref.3
Node 21 Deflection – Z -0.351 -0.351 -0.352 -0.352
Node 21 Deflection – Y 0.0366 0.0366 0.0367 0.0367
Beam 8 Axial 80.0 80.0 80.0 80.1 0.13%
Beam 24 Axial 57.9 57.9 57.8 57.9

 